Akčné ponuky na váš e-mailI/O ports and slots
16 SFP 100/1000 Mbps ports
8 SFP dual-personality ports; 100/1000BaseX or 100/1000BASET RJ-45 Combo Ports
4 SFP+ fixed 1000/10000 SFP+ ports
Additional ports and slots
1 RJ-45 serial console port
Power supplies
2 power supply slots
1 minimum power supply required (ordered separately)
Physical characteristics
Dimensions
17.32(w) x 14.17(d) x 1.72(h) in (44 x 36 x 4.36 cm) (1U height)
Weight
17.64 lb (8 kg)
Memory and processor
1 GB SDRAM, 128 MB flash; packet buffer size: 1.5 MB
Mounting and enclosure
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included)
Performance
1000 Mb Latency < 5 µs
10 Gbps Latency < 1.5 µs
Throughput 96 Mpps
Routing/Switching capacity 128 Gbps
Routing table size 512 entries (IPv4), 256 entries (IPv6)
MAC address table size 16384 entries
Reliability
MTBF (years) 52.79
Environment
Operating temperature 32°F to 113°F (0°C to 45°C)
Operating relative humidity 10% to 90%, noncondensing
Nonoperating/Storage temperature -40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity 5% to 95%, noncondensing
Acoustic Low-speed fan: 47.1 dB, High-speed fan: 50.7 dB; ISO 7779
Electrical characteristics
Frequency 50/60 Hz
Maximum heat dissipation 102/204 BTU/hr (107.61/215.22 kJ/hr), for AC Powered units. For DC powered units heat dissipation is 130BTU/hr min, 232BTU/hr max.
AC voltage 100 - 240 VAC
DC voltage -48 to -60 VDC
Current 5 A
Maximum power rating 60 W
Idle power 30 W
Notes
Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Power Ratings for AC Power Suppply indicated above.
For DC input power, Idle Power is 38W and Max is 68W.
DC Max input current is 8A. Units are supplied without a power supply. Customer must buy 1 or 2 JD362A(AC) or JD366A (DC) power supply.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS Compliance
Emissions
EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A; EN 61000-4-11:2004; ANSI C63.4-2009; EN 61000-3-3:2008; VCCI V-4/2012.04; EN 6100-3-2:2006+A1:2009 + A2:2009; EN 61000-3-2:2006+A1:2009+A2:2009 ; EN 61000-4-3:2006; EN 61000-4-4:2012; EN 61000-4-5:2006; EN 61000-4-6:2009; AS/NZS CISPR 22:2009 Class A; CISPR 22:2008 Class A; EN 55022:2010 Class A; EN 61000-4-29: 2000; CISPR 24:2010; EN 300 386 V1.6.1; VCCI V-3/2013.04 Class A
Immunity
Generic EN 55024
ESD EN300 386
Management
IMC - Intelligent Management Center; command-line interface; Web browser; SNMP Manager
Services
Refer to the HP website at: www.hp.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.
.